Common Soil Probe Wiring Guidelines
For your convenience, the description of the probe wire colors is as described in the table below. But, always consult with the probe’s manufacturer for the definitive reference, in case the color assignment changes.
- SDI-12 Data connects to terminal “SDI-12”
- Power connects to terminal “VAUX”
- Ground connects to terminal “GND”
Probe Manufacturer
| LSMP/CSMP connectors
|
SDI-12
| GND
| VAUX
|
Sentek
| white
| green
| red
|
Greenshield
| green
| yellow
| brown
|
HSTi
| blue
| green
| brown
|
AquaCheck
| blue
| green/yellow
| brown
|
EnviroPro
| blue
| black
| red
|
METER/Decagon
| orange
| bare
| brown
|
Important: Please note that while the SDI-12 standard is capable of connecting multiple SDI-12 probes to the same master logger, LSMP device supports one SDI-12 probe at a time. Do not connect more than one probe. Additionally, ensure that the SDI-12 address of the probe must be “0”.
To learn more, see the LSMP Device User Manual and the CSMP Device User Manual
Related Articles
Instruction Manual for Zenseio LSMP-2103 Device
1. Document revision 1.35 January 15, 2026 Copyright 2017-2026 Zenseio LLC 2. Introduction Zenseio LoRa Soil Moisture Pro (LSMP) device is providing long-range telemetry for SDI-12 soil moisture probes and other commonly used industrial sensors using ...
Which Soil Moisture Probes are Compatible with Zenseio Devices?
Currently, Zenseio LSMP and CSMP devices supports the following SDI-12 soil moisture probe brands: Sentek Greenshield AquaCheck HSTi GroPoint TriBus Meter Group / Decagon Other types of probes and sensors may be readily supported through ...
Connecting a Soil Moisture Probe to your LSMP Device
To learn how to connect a soil moisture probe (or another SDI-12 compatible sensor) to your LSMP device, see the Soil Moisture Probe Setup section of the LSMP Device Manual.
Instruction Manual for Zenseio CSMP-4103 Device
1. Document revision 1.15 January 15, 2026 Copyright 2017-2026 Zenseio LLC 2. Introduction Zenseio Cellular Soil Moisture Pro (CSMP) device is providing long-range telemetry for SDI-12 soil moisture probes and other commonly used industrial sensors ...
Zenseio Solar Panel Wiring - Quick Start Guide
Wiring Instructions Remove the rubber plug from the small cable gland. Make sure the extension cable is not connected to the solar panel. Thread the solar panel extension cable through the small cable gland. Connect the red wire to the “+” (positive) ...