What types of GPI Sensors are compatible with Zenseio Devices?
Zenseio Devices can monitor many different types of commonly used sensors via GPI input: tipping rain buckets, pressure switches, pressure transducers/transmitters, flow meters, temperature sensors, and others. There are 3 independent general purpose inputs (GPI’s) that can be configured via the mobile phone app to read several types of analog and digital interfaces, with capabilities as shown in the table below.
Sensor Interface | GPI1 | GPI2 | GPI3 |
Level Trigger | Yes | Yes | Yes |
Pulse Counter | Yes | Yes | Yes |
0-24V Voltage | No | Yes | Yes |
4-20mA Current | No | Yes | No |
Thermistor | No | No | Yes |
Note there are some differences in capability between GPIs and plan your setup accordingly. For example, if you want to configure your device to collect data from a level trigger, thermistor, and a 4-20mA current sensor like a pressure transducer, then you should reserve the GPI3 input for the Thermistor and the GPI2 input for the 4-20mA current sensor.
Note: Default GPI configuration is “Any Level Trigger” (activated on both rising and falling edges) for GPI1 and GPI2, and “Thermistor” for GPI3. Default configuration for VAUX is 8V. WARNING: if using sensors requiring different configuration than these factory-programmed defaults, VAUX and GPI settings have to be configured with Android app (as in Section 5) before connecting any sensors to the header or they may get damaged from overvoltage.
|
Related Articles
How to Use Modbus RS-485 Sensors with Zenseio LSMP and CSMP Devices
We're thrilled to announce the integration of Modbus RS-485 industrial sensor support with firmware version 23 for the LSMP-2103 and CSMP-4103 devices. This update opens up new possibilities for industrial applications by allowing these devices to ...
Which Soil Moisture Probes are Compatible with Zenseio Devices?
Currently, Zenseio LSMP and CSMP devices supports the following SDI-12 soil moisture probe brands: Sentek Greenshield AquaCheck HSTi GroPoint TriBus Meter Group / Decagon Other types of probes and sensors may be readily supported through ...
Configuring Alerts for GPI Sensors Using the Zenseio Mobile App
I/O Mode - selects the functionality of the input: Off - the input is ignored Digital - a weak pullup voltage is supplied by device on the GPI input, and the input is sampled at Sensor Read Intervals. If the voltage is pulled externally close to 0 V ...
Instruction Manual for Zenseio LSMP-2103 Device
1. Document revision 1.33 January 3, 2022 Copyright 2017-2023 Zenseio LLC 2. Introduction Zenseio LoRa Soil Moisture Pro (LSMP) device is providing long-range telemetry for SDI-12 soil moisture probes and other commonly used sensors using LoRaWAN ...
Instruction Manual for Zenseio CSMP-4103 Device
1. Document revision 1.13 January 3, 2022 Copyright 2017-2023 Zenseio LLC 2. Introduction Zenseio Cellular Soil Moisture Pro (CSMP) device is providing long-range telemetry for SDI-12 soil moisture probes and other commonly used sensors using ...