Debug No Connectivity Issue on Multitech Conduit LoRa Gateway (ethernet only version)

Debug No Connectivity Issue on Multitech Conduit LoRa Gateway (ethernet only version)

If the Multitech (ethernet-only) gateway completely stops connecting to the internet, not just our LoRa network server. Since this is an Ethernet-only gateway, the most likely failures are:
  1. Power failure (ie. PoE Injector failure, mains power loss - it could be switched off, power cable damage) 
  2. Internet connection failure (ie. Ethernet cable damage, Ethernet router/switch failure, Wi-Fi bridge failure - if you are using it)
  3. Temporary issue with the gateway

First check #1: look at the gateway LEDs, if they are turned on or flashing, power supply should be OK. 
If #1 is OK, then check #2. Best to unplug Ethernet cable from the gateway and connect to a laptop. If the laptop can connect with the internet via the Ethernet connection, then #2 is not likely the issue.
If #2 is OK, then unplug Ethernet cable between the gateway and PoE Injector (at whichever end it is easier to do) and plug it back after a minute to reboot the gateway. This should clear up #3 issue most of the time.

We had several customers experiencing PoE Injector failures in extreme cold or hot weather condition and resolving the issue by replacing the PoE Injector with the industrial-grade one. The bundled PoE Injectors are only meant for indoor use (ie. used in room temperature with low humidity). For outdoor installation (especially in extreme temperatures below 30°F or above 100°F), we always recommend appropriately rated PoE Injectors.
    • Related Articles

    • Multitech Conduit Gateway Troubleshooting

      Multitech Conduit LoRaWAN gateway should be connected to "P+D/OUT" port of the PoE Injector. If you have internet (from a router's ethernet), you can connect it to "Data/IN" of the PoE Injector. If you don't connect internet line to "Data/IN", the ...
    • Setting Up a Multitech Gateway: Hardware Installation Guides & Tips

      When setting up and installing a MultiTech Gateway for use with your Zenseio device, we advise referring to the official hardware installation guide before mounting. Note that the installation process can vary by model, so be sure you are using the ...
    • RAK 7258 Indoor LoRaWAN Gateway Firmware Upgrade

      RAK gateways don't have remote management capabilities. But, it's pretty easy to upgrade the firmware yourself. Find the IP address of that gateway on your network. You can log into your router to see the assigned IP address to RAK Download this ...
    • Instruction Manual for Zenseio LSMP-2103 Device

      1. Document revision 1.33 January 3, 2022 Copyright 2017-2023 Zenseio LLC 2. Introduction Zenseio LoRa Soil Moisture Pro (LSMP) device is providing long-range telemetry for SDI-12 soil moisture probes and other commonly used sensors using LoRaWAN ...
    • How can I quickly test if my device is working?

      You can test if your CSMP or LSMP device is functioning by pressing the user button located inside its case. This will cause your device to attempt to connect to Zenseio's servers and make a transmission according to the device's configuration. This ...