Debug No Connectivity Issue on Multitech Conduit LoRa Gateway (ethernet only version)

Debug No Connectivity Issue on Multitech Conduit LoRa Gateway (ethernet only version)

If the Multitech (ethernet-only) gateway completely stops connecting to the internet, not just our LoRa network server. Since this is an Ethernet-only gateway, the most likely failures are:
  1. Power failure (ie. PoE Injector failure, mains power loss - it could be switched off, power cable damage) 
  2. Internet connection failure (ie. Ethernet cable damage, Ethernet router/switch failure, Wi-Fi bridge failure - if you are using it)
  3. Temporary issue with the gateway

First check #1: look at the gateway LEDs, if they are turned on or flashing, power supply should be OK. 
If #1 is OK, then check #2. Best to unplug Ethernet cable from the gateway and connect to a laptop. If the laptop can connect with the internet via the Ethernet connection, then #2 is not likely the issue.
If #2 is OK, then unplug Ethernet cable between the gateway and PoE Injector (at whichever end it is easier to do) and plug it back after a minute to reboot the gateway. This should clear up #3 issue most of the time.

We had several customers experiencing PoE Injector failures in extreme cold or hot weather condition and resolving the issue by replacing the PoE Injector with the industrial-grade one. The bundled PoE Injectors are only meant for indoor use (ie. used in room temperature with low humidity). For outdoor installation (especially in extreme temperatures below 30°F or above 100°F), we always recommend appropriately rated PoE Injectors.
    • Related Articles

    • Multitech Conduit Gateway Troubleshooting

      Multitech Conduit LoRaWAN gateway should be connected to "P+D/OUT" port of the PoE Injector. If you have internet (from a router's ethernet), you can connect it to "Data/IN" of the PoE Injector. If you don't connect internet line to "Data/IN", the ...
    • Reducing Signal Interference for a LoRa Gateway

      If the gateway is missing lots of LoRa messages, it could be due to strong radio interference from other telecomunications equipment mounted close to the gateway. Relocating the gateway as far as you can from the interference source would be the best ...
    • What do the LED lights mean on Multitech Conduit IP67 gateways?

      LED Indicators Label Name Description PWR Power Solid (constant) green if unit is on indicating that DC power is present. STATUS Power Status Default condition: LED blinks when mLinux is fully loaded. LS (or L1) Link Status Varies with radio model. ...
    • Setting Up a Multitech Gateway: Hardware Installation Guides & Tips

      When setting up and installing a MultiTech Gateway for use with your Zenseio device, we advise referring to the official hardware installation guide before mounting. Note that the installation process can vary by model, so be sure you are using the ...
    • Installing a Multitech Gateway

      In order to setup your Multitech Gateway with your Zenseio Device, follow these simple steps: Fill-out request form, so Zenseio Support can onboard your Gateway in our system. Insert the SIM card into the SIM slot under the round clear plastic window ...